NTA 1000 and NTA 1300 148-528Q 7/29/2004
Great Plains Mfg., Inc.
Bleeding Marker Hydraulics
To fold properly, the marker hydraulics must be free of air.
If the markers fold in jerky, uneven motions, follow these
steps.
!
CAUTION!
You may be injured if hit by a folding or unfolding marker.
Markers may fall quickly and unexpectedly if the hydraulics fail.
Never allow anyone near the drill when folding or unfolding the
markers.
Check that tractor hydraulic reservoir is full. Marker hy-
draulic capacity is 1.2 liters (.32 gallons).
1. With both markers lowered into field position, loosen
hydraulic-hose fittings at rod and base ends of marker
cylinders. If applicable, loosen fittings on back side of
sequence valve.
IMPORTANT: Never bleed an O-ring fitting. Instead,
bleed a nearby pipe or JIC fitting.
2. With tractor idling, activate tractor hydraulic valve until
oil seeps out around a loosened fitting. Tighten that fit-
ting.
IMPORTANT: JIC fittings do not require high torque. JIC
and O-ring fittings do not require sealant. Always use liq-
uid pipe sealant when adding or replacing pipe-thread fit-
tings. To avoid cracking hydraulic fittings from over
tightening, do not use plastic sealant tape.
3. Reactivate tractor hydraulic valve until oil seeps out
around another loosened fitting. Tighten that fitting.
Repeat process until all loosened fittings have been
bled and tightened.