Great-plains YP825AR Material Rate User Manual Page 72

  • Download
  • Add to my manuals
  • Print
  • Page
    / 124
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 71
68 YP825AR Table of Contents Metric Charts Great Plains Manufacturing, Inc.
401-923B Table of Contents Metric Charts 2013-11-11
Install Orifice Plates
Refer to Figure 31
9. Insert the plate inside the gasket supplied with the
nozzle . Insert the gasketed plate with the legend
side facing out the nozzle outlet (typically up).
In general, the orifice needs to be small enough to
create enough pressure in the manifold to operate the
check valves in the boom clamps, but not so much that
the system dumps product at the boom relief valve.
The recommend operating pressure is: 15 to 40 psi
Using an orifice size too large can result in unequal flow
at rows, intermittent flow, and flow stoppage at rows
where pressure falls below the 8 psi required to open the
clamp check valve. Using a size too small can cause
excess back-pressure resulting in material dumping at
the boom relief valve.
Use the same size at all active rows.
Row Shutoff
Refer to Figure 31
Unused drop lines may be shut off by replacing the
nozzle with a Great Plains 832-042C cap . Twin row
boom systems separately include caps for half the rows.
When installing a cap:
It is not necessary to remove the gasketed orifice plate
from inside the clamp. The cap includes its own gasket
that seals at the end of the clamp port.
Use a tie wrap or other line to secure the loose nozzle
and drop line tubing to the boom.
Adjust pump and/or orifice plates for new rate and row
spacing.
Mis-Application or Material Loss Risk:
Do not apply materials after row shut-off or row turn-on
without first reviewing setup. Merely changing the number of
active rows does not change the application rate. If pump and/
or orifice size changes are not also made, pressures could be
too low or too high.
Equipment Damage Risk:
Plant at or below 8.8 mph (14 kph) with the standard high rate
sprockets installed. The pump is rated for 550 rpm maximum,
which is exceeded at and above 8.9 mph.
Note: Replacement nozzles include gaskets.
Gaskets may also be ordered separately as Great
Plains part number CP18999-EPR.
Agricultural Chemical Hazard:
Wear protective gloves when changing orifice plates and
strainer screens. Consult material manufacturer or supplier
documents for proper handling and steps to take if skin contact
occurs.
Figure 31
Fertilizer Orifice Plate
29984
Orifice Part Port Port
Size Number Diameter Area
20 832-052C 0.020 in 0.20 mm²
28* 832-056C 0.028 in
0.40 mm²
34* 832-053C 0.034 in 0.59 mm²
48* 832-054C 0.048 in 1.17 mm²
59 832-057C 0.059 in
1.76 mm²
80 832-055C 0.080 in 3.24 mm²
98 832-059C 0.098 in 4.87 mm²
29993* Sizes standard in many fertilizer bundles.
Check your accessories before ordering.
1
5
3
2
4
2
3
1
4
3 5
Page view 71
1 2 ... 67 68 69 70 71 72 73 74 75 76 77 ... 123 124

Comments to this Manuals