Great Plains Manufacturing, Inc. Contents Index Operating Instructions 55
04/04/2011 Contents Index 166-283M
Air Systems Overview
1. Hydraulic Fan (page 56)
The fan generates the air flow required to deliver
material to the rows. Speed is adjusted via the trac-
tor circuit. Output is monitored via rpm , pressure
gauge and pressure sensor .
2. Fan RPM Sensor (page 82)
The seed monitor reports fan rpm based on this sen-
sor. Although it is accurate for rate, it cannot detect a
fan running in reverse.
3. Diverter Vane (page 84)
Present only on dual-hopper drills, this controls air-
flow balance between the meters. This may need
adjustment with dissimilar material metering.
4. Manifold Pressure Gauge(s) (page 82)
There is one gauge per hopper, mounted for ease of
observation from the tractor cab. These report
whether or not the air system is within recommended
limits. On dual-hopper systems, the gauges assist in
setting the diverter vane .
5. Meter Inlet Manifold (page 84)
Fan air is divided (or further divided) into equal flows
for each meter inlet port .
6. Hopper (page 48)
Material (seed or fertilizer) flows into the top of the
seed meter .
7. Pressure Balance Lines
Each hopper contains an internal pressure-balanc-
ing system to equalize pressure above and at the
base of the material.
8. Hopper Pressure Sensor
This sensor signals the seed monitor, which can
alarm if the hopper pressure goes out of limits. A
dual hopper drill has two sensors.
9. Seed Meter
The meter combines material with air flow. It also has
features for rate Range, calibration and clean-out.
10. Flute Shaft (page 163)
Two (and optionally; three or four) sets of flute “stars”
control the flow of seed from the hopper into the air
streams.
11. Flute Shaft RPM Sensor (page 71)
This shaft encoder provides metering rate data, stop-
page alarms, and is used by the optional Variable
Rate Kit to control metering rate.
12. Meter Outlet Ports
Material falls from the meter flutes into the air
streams flowing from inlet manifold to outlet ports.
Each port is a separate compartment.
13. Single-Shoot Y-Tube
A two-hopper drill may optionally have the output of
both meters combined into a single stream to a sin-
gle set of towers. The flows combine at Y-tubes
behind the meters.
14. Primary Seed Hose
Four (single-hopper/shoot) or eight (double-shoot)
hoses deliver seed from the meters to the
towers .
15. Distribution Tower
The riser tube and distribution rings have features to
evenly divide the primary hose material flow into
multiple secondary hose flows. There are four
towers on single-hopper and single-shoot drills, and
eight towers on double-shoot drills.
16. Blockage Sensor
Each tower outlet port has a sensor that detects
material passage and signals the seed monitor. The
primary function of this sensor is to trigger an alarm
on flow stoppage.
17. Secondary Seed Hose
These hoses deliver material from a tower outlet port
to a seed tube or fertilizer tube .
18. Tramline Diverter (Option, page 142)
19. Opener Seed Tube
Seed from hopper I (and hopper II on single-shoot
drills) is delivered in-furrow ahead of the seed firmer.
20. Opener Fertilizer Tube (page 93)
On a dual-hopper double-shoot drill, the material
from hopper II is delivered to this tube above the
seed firmer and furrow.
1 Hydraulic Fan 8 Hopper Pressure Sensor 15 Distribution Tower
2 Fan RPM Sensor 9 Seed Meter 16 Blockage Sensor
3 Diverter Vane 10 Flute Shaft 17 Secondary Seed Hose
4 Manifold Pressure Gauge 11 Flute Shaft RPM Sensor 18 Tramline Diverter
5 Meter Inlet Manifold 12 Meter Outlet Ports 19 Opener Seed Tube
6 Hopper 13 Single-Shoot Y-Tube 20 Opener Fertilizer Tube
7 Pressure Balance Lines 14 Primary Seed Hose
2
5 8
3
5
9
10
9
15
17
19 20