Great Plains Mfg., Inc. Front Parts Installation Instructions 17
6/23/2010 Front Parts 166-263M
Actuator Channel Setup
85. Assign material.
86. Type must be set to GRAN SEED CONTROL or
GRAN FERT CONTROL.
87. Check that other setting are as Required, and
reflect the actual configuration of the implement.
Example Channel Setup:
Parameter Value Comment
CHANNEL 1 or 2
Per meter
being config-
ured
Type
GRAN SEED CONTROL
or
GRAN FERT CONTROL
One of these
Required
Material
Name
Wheat HRW
or
11-52-0
Example
user-speci-
fied names
Control
Mode
Auto Required
Drive Type Zero Max 1 or 2 Required
Drive Freq. 40 Hz Required
Input Fliter 50 % Required
Sensor
Constant
360 PUL/REV Required
Gear Ratio 1 Required
Meter Gear
Range
LOW or HIGH
One of these
Required
# Seed
Rows
32, 36, 40, 48, 50, 60, 65,
66, 80
read-only, per
implement or
drill model
Channel
Width
(set to swath of imple-
ment or drill, in inches or
cm)
Required
Flush
Enable
Disabled Data not used
Pre-
charge(+)\D
elay(-)
0.0 SEC Data not used