Great-plains 2025P Operator Manual User Manual Page 97

  • Download
  • Add to my manuals
  • Print
  • Page
    / 166
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 96
8/14/2006
118-928M
95
Veris Drive Operating Instructions
Troubleshooting GPS-based Seed-
ing with SiteMate
1. No Rx rate appears on SiteMate
has field been selected? Select VRT file (see
SiteMate Settings, Step 5)
check recipe to verify that it is valid by viewing At-
tributes for each zone in SiteMate
if recipe calls for zero rate as the default, do you
have GPS signal, or are you outside of field?
2. Rx rate appears on SiteMate, but no Applied Rate.
make sure “Go” button on SiteMate is pressed.
(button should read “Stop” when recipe is being
sent to GP Console)
you must be planting in order for Applied Rate to
appear.
3. Rx rate appears on SiteMate but not on GP Con-
troller Console.
make sure GP Controller Console is set to VR
Mode (seeFigure 129, page 90)
double-check all cable connections
check Nominal rates on both the SiteMate (SiteM-
ate Settings, Step 4), and on the GP Controller
Console (GP Settings, Step 2) These must be set
to the same number.
4. Rates on GP Controller Console and on SiteMate
do not match.
check Nominal rates on both the SiteMate (SiteM-
ate Settings, Step 4), and on the GP Controller
Console (GP Settings, Step 2) These must be set
to the same number.
Re-check GP calibration number, with metering
wheel and row spacing.
The recipe rates from SiteMate are in 4% incre-
ments. If the two rates are within this 4% range,
the units are operating normally.
Check the Conversion number (SiteMate Settings,
Step 2). If the recipe requires a target conversion
number, i.e. the recipe is for 25 which means
25,000 seeds/acre, the target conversion number
will be 1000. In this case the Nominal Rate in
SiteMate and the GP Console should be near
25,000. See SiteMate Settings, Step 4 for calculat-
ing Nominal Rate.
5. Population Monitor rate does not match GP Con-
troller Console.
Make certain that SiteMate and GP Controller
Console agree. If not, see Troubleshooting step 4.
Re-check GP calibration number, with metering
wheel and row spacing.
Re-check planter monitor settings: calibration
number, row spacing, number of rows, swath
width, seed, etc.
On small seeds and/or high rates, if population
monitor consistently indicates a lower population
than the GP Controller Console, contact monitor
manufacturer for performance specs for that appli-
cation.
6. GPS signal is not being received by SiteMate:
verify that GPS serial port (which is also the dock-
ing port) is not set to PC connection only (Start/
Settings/Communications/PC Connections-check
GPS settings in Configure/Settings/GPS settings/
COM (typically COM1, 4800 Baud, 8 data bits,
Parity None, and Stop Bits 1)
Click Data tab to view GPS details
Page view 96
1 2 ... 92 93 94 95 96 97 98 99 100 101 102 ... 165 166

Comments to this Manuals

No comments