General Troubleshooting
Problem Cause Solution
Population
Alarms
See “Population Troubleshooting Charts” on page 86.
Excess Seed
Remaining
See “Population Troubleshooting Charts” on page 86.
Field size different. After ruling out population problems, re-check geography.
Excessive gaps between planter
passes.
Adjust marker, page 151.
Seed
Consumption
Too High
See “Population Troubleshooting Charts” on page 86.
Field size different. After ruling out population problems, re-check geography.
Excessive overlap.
Irregular shaped field.
Adjust marker, page 151.
Rows Not
Planted
If not detected by optional seed
monitor, check for plugged row-unit
seed tube
Lift planter, expose bottom of seed tube and clean out.
Uneven
seed
spacing
See “Population Troubleshooting Charts” on page 86.
Excessive field speed. Reduce field speed.
Unclean seed. Use clean seed.
Damaged seed tube Inspect; repair or replace.
Seed-Lok
®
plugging. Lock up Seed-Lok
®
, page 81.
Row-unit discs not turning. See “Row-unit discs not turning freely” in this
Troubleshooting chart.
Worn/rusted sprockets and/or chain
idler or bearings.
Check and replace any worn/rusted sprockets or chain idlers.
Partially plugged row-unit seed tube. Lift up planter, expose bottom of seed tube and clean out.
Lack of proper seed lubrication on
seed.
See “Seed Lubricant” on page 127.
Uneven
seed depth
Excessive field speed. Reduce field speed.
Planting conditions too wet. Wait until drier weather.
Incorrect coulter depth setting. See coulter manual or set unit mounted coulter.
Excessive or improper row unit down
pressure spring setting.
See “Row Unit Down Pressure” on page 66.
Damaged seed tubes. Check seed tubes for damage.
Seed-Lok
®
building up with dirt. Lock up Seed-Lok
®
, page 81.
Row-unit not penetrating low spots. Adjust row-unit, see instructions beginning on page 66.
Rough planting conditions. Rework the field.
Seed firmer not in place and set to
correct tension.