2025P, 2020P Bedded, and
2010HDP
118-928M
8/14/2006
40
Cleaning Out Meters
NOTE: Shut off sliding seed tubes before at-
tempting to clean out seed meters.
For seed meter clean out:
1. Position tarp or buckets under the opener(s)
whose meter(s) you will be cleaning out.
Refer to Figure 52
2. Remove retaining clip and pull pin.
Refer to Figure 53
3. Pull up on meter clean out door to open.
4. When meter is empty, push meter clean out
door back to its original position to close.
NOTE: You may need to shake the clean out
door a little before closing to make sure all
seeds fall out.
Refer to Figure 54
5. Replace pin and retaining clip.
Figure 52
Meter Clean Out
22856
Retaining clip
Clean out door
Figure 53
Meter Clean Out Door
22857
Clean out door
Figure 54
Meter Clean Out Pin
22858
Page view 41