Great-plains NP4000B Operator Manual User Manual Page 117

  • Download
  • Add to my manuals
  • Print
  • Page
    / 200
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 116
Great Plains Manufacturing, Inc. Table of Contents Index Troubleshooting 113
2014-05-14 Table of Contents Index 417-199M
Hydraulic Drive Pump Troubleshooting
The Ace Pump Instruction manual (HYD-MAN) and the
Raven SCS 450 Installation, Operation and Service
manual (016-0159-831) have additional troubleshooting
information.
High Rate
Ground drive on High Range when
rate requires Low
Exchange Range sprockets (page 103).
Dial setting incorrect Re-check Range and Dial settings for rate.
Low Manifold
Pressure
Relief valve set too low Adjust relief valve (page 103).
Ground drive on Low Range when
rate requires High
Exchange Range sprockets (page 103).
Field speed too low Increase speed or reduce orifice plate size.
Ground drive wheel or chains
slipping
Check condition of arm and chains. Check operating height
of applicator (may be too high). If soil is too wet, try
reconfiguring for a lower manifold pressure, or wait for dryer
conditions.
Product
Dumping at
Relief Valve
Rate, speed or material viscosity too
high for orifice plate size
Re-check pump rate determination, Range sprocket, pump
dial and console setup (Option). If correct, replace orifice
plates with a larger size (page 100).
Orifice plates clogged Use larger plates (page 100) or finer strainer screen
(page 102).
Relief valve set too low Adjust relief valve (page 103).
Tines plugged Clean out tine tubes
Material slushy due to low
temperature, or actual ice in boom
Wait for warmer conditions.
High Manifold
Pressure
Ground drive on High Range when
rate requires Low
Exchange Range sprockets (page 103).
Field speed too high Reduce speed or increase orifice plate size.
Problem Cause Solution
Problem Cause Solution
Rate Alarm,
Low
System not fully charged Prime system. Check for blocked air bleed line on standard
first pump. Open petcock on user-plumbed second pump.
One or more manual valves not fully
open
Suspend operations. Check all manual valves from nurse
tank withdrawal valve (if any) to inlet shut-off valve.
Control valve malfunction or harness
status
Check harness connections and fuses.
Use console SELF-TEST mode to command rate to zero.
Check indicator at control valve.
Command rate to maximum. Check valve open.
Rate Alarm,
High
Incorrect VALVE CAL for Control
Valve or METER CAL for flow meter.
Recheck console setup against values provided for
components (page 44).
Control Valve failed, or harness
status
Check harness connections and fuses.
Use console SELF-TEST mode to command rate to zero.
Check indicator at control valve.
Command rate to maximum. Check valve open.
Page view 116
1 2 ... 112 113 114 115 116 117 118 119 120 121 122 ... 199 200

Comments to this Manuals

No comments