Great-plains NP4000B Operator Manual User Manual Page 48

  • Download
  • Add to my manuals
  • Print
  • Page
    / 200
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 47
44 2013+ NP4000/A/B Table of Contents Index Great Plains Manufacturing, Inc.
417-199M Table of Contents Index 2014-05-14
Meter / Variable Rate Setup (Option)
This topic presumes that the Nutri-Pro
®
applicator has
one or more Raven SCS 450 consoles, speed radar, flow
meter, pressure sensor, section control valves, and, for
anhydrous models, single or dual Raven AccuFlow™
metering system. It also presumes that the console has
been installed in the tractor cab per “Console
Installation” on page 179.
If the Nutri-Pro
®
applicator has dealer- or user-provisioned
controller or metering, carefully follow supplier
documentation for installation, setup, use and maintenance.
This Nutri-Pro
®
manual (417-199M) cannot describe your
system. Great Plains cannot assume any liability for results
with equipment not supplied by Great Plains.
Before first field use of the SCS 450, it must be
programmed with data specifying the system
configuration, consisting of various “CAL” numbers and
user elected “RATE” numbers. See the Raven SCS 450
manual for display interpretation, and see the manual or
the Calibration Card for the keystroke sequence for
setting each of these values.
This data is retained as long as the SCS 450 remains
connected to battery power. If power is removed for
electrical work, long term tractor parking or welding, the
data is lost and must be re-entered.
SCS 450: BOOM CAL
Anhydrous models without section control have one
“boom section” (BOOM 1, whether single- or
dual-cooler). The BOOM CAL number is simply the
applicator swath on single-section applicators. See the
table on page 46.
Hydraulic pump models and anhydrous models with
section control have three boom sections. See the table
on page 46.
SCS 450: SPEED CAL
A speed sensor connection to the Raven SCS 450 is
required. Perform a calibration per the manuals for the
sensor and the SCS 450.
A speed sensor input allows the SCS 450 to determine
and control application rates at arbitrary field speeds.
Note: The Great Plains Raven AccuFlow™ and SCS 450
bundles do not include a speed sensor, nor the
cable necessary to connect a Raven-compatible
sensor or radar to the SCS 450 See page 149 for
an available radar kit. See page 169 for harness
cables available from Great Plains or Raven.
Note: Two-product applicators using two SCS 450
consoles usually require an additional Y-cable.
L29
L31
L32
L30
Figure 19
Raven Flow Control and SCS 450
32020
Page view 47